Abstract

Pursuant international standards such of the European ones, the nondestructive examinations have to be worked out by the most possible accuracy and repeatability, that allow the difference making between the admitted indications, whatever they involve, dump or rejection.
The activity may be carried out with positive results, only, after providing:
- suitable tests and settlements of assay equipment by the agency of calibration and reference blocks;
- insurance for good training of working staff.
With the view of touch of this challenge the CALIST framework program was made.

Creative Commons License

Downloads

Download data is not yet available.

References

[1]. Tovică M., Metode de evaluare a componentelor structu-rilor metalice cu defecte, pe baza conceptelor mecanicii ruperilor. Curs ISIM Timişoara, 2000 România,
[2]. Stanciu Cr., Studiu documentar şi de marketing privind blocurile de etalonare şi referinţă. S.C. UZINSIDER Engineering Galaţi, 2003.
[3]. Ciobanu E., Ciobanu M., Certificarea produselor conform reglementărilor Uniunii Europene. Revista Tribuna Calităţii nr. 4-5, Anul IV, aprilie-mai 1999, p. 52-62, ISSN 1224-3116.
[4]. Volker D., Platte M., Vogt M., Controlul ultrasonic. Principii şi aplicaţii industriale, Focşani, 1998.
[5]. SR EN ISO 17025,: Cerinţe generale pentru competenţa laboratoarelor de încercare şi etalonare, 2001.
[6]. Markucic D.,.Mudronja V., Sanjin M., Runje B. Quality Requirements for Ultrasonic Testing Calibration Blocks NDT. Net-vol. 8, no. 3, p. 1-8, 2003.
[7]. Millea A., Informaţie şi incertitudine în măsurători. Editura Tehnică. Seria tehnică, 1981, Bucureşti.
[8]. Bohăţiel T., Năstase E., Defectoscopie ultrasonică fizică şi tehnică, Tehnică Bucureşti, 1980, România.
Published
2006-05-15
How to Cite
1.
STANCIU C, PETREA I, SILVICA H. Calibration and Reference Blocks Used in Nondestructive Ultrasound Examination, According to New European Union Requirements. The Annals of “Dunarea de Jos” University of Galati. Fascicle IX, Metallurgy and Materials Science [Internet]. 15May2006 [cited 26Dec.2024];29(1):63-6. Available from: https://gup.ugal.ro/ugaljournals/index.php/mms/article/view/3230