Emissions of Carbon Monoxide and Suspended Particles from the Steel Foundry of S.C. PROMEX S.A.
Keywords:
air pollution, steel foundry, special steels, potential risk
Abstract
The purpose of this article is to analyse the level of pollution of the installations related to the steel foundry operated by S.C. PROMEX S.A. Brăila, activity carried out on site and facilities put into operation, to assess the impact of these activities on the quality of environmental factors, potential risk and measures taken to prevent and reduce pollution. The determination of carbon monoxide (mg/m3) and Suspended particles (mg/m3) was done during 2016-2019.
Downloads
Download data is not yet available.
References
[1]. Stefana E., Cocca P., Marciano F., Rossi D., Tomasoni G. A., Sustainability, 11, 7245, 2019.
[2]. ***, International Organization for Standardization. ISO 14001: Environmental Management Systems-Requirements with Guidance for Use, International Organization for Standardization: Geneva, Switzerland, 2015.
[3]. Patange G., Khond M., Eur. Sci. J., 9, p. 241-252, 2013.
[4]. Dilip A., Tatsutani M., SAPI EN. S. Surveys and Perspectives Integrating Environment and Society, no. 2.1, 2009.
[5]. Zheng X., Ranran W., Richard W., Can W., Edgar G. H., Nature Geoscience, 11 (4), 269, 2018.
[6]. Fayomi O. S., Ayoola A. A., Morounfoluwa J., Akinwumi I. I., Published under licence by IOP Publishing Ltd IOP Conference Series: Materials Science and Engineering, vol. 640, no. 1, 2019.
[7]. Wang Y., Ying Z., Lu S., Xiangyu L., Lei D., Chengwen W., Tianyou H., Environmental Science & Technology, 45 (15), p. 6539-44, 2011.
[8]. Pal P., Girish S., Abhishek N., Sanjeev S., Journal of Cleaner Production, 16 (12), p. 1264-74. https://doi.org/https://doi.org/10.1016/j.jclepro.2007.06.021, 2008.
[9]. Olmez G. M., Dilek F. B., Karanfil, T., Yetis U., J. Clean. Prod., 130, p. 195-201, 2016.
[2]. ***, International Organization for Standardization. ISO 14001: Environmental Management Systems-Requirements with Guidance for Use, International Organization for Standardization: Geneva, Switzerland, 2015.
[3]. Patange G., Khond M., Eur. Sci. J., 9, p. 241-252, 2013.
[4]. Dilip A., Tatsutani M., SAPI EN. S. Surveys and Perspectives Integrating Environment and Society, no. 2.1, 2009.
[5]. Zheng X., Ranran W., Richard W., Can W., Edgar G. H., Nature Geoscience, 11 (4), 269, 2018.
[6]. Fayomi O. S., Ayoola A. A., Morounfoluwa J., Akinwumi I. I., Published under licence by IOP Publishing Ltd IOP Conference Series: Materials Science and Engineering, vol. 640, no. 1, 2019.
[7]. Wang Y., Ying Z., Lu S., Xiangyu L., Lei D., Chengwen W., Tianyou H., Environmental Science & Technology, 45 (15), p. 6539-44, 2011.
[8]. Pal P., Girish S., Abhishek N., Sanjeev S., Journal of Cleaner Production, 16 (12), p. 1264-74. https://doi.org/https://doi.org/10.1016/j.jclepro.2007.06.021, 2008.
[9]. Olmez G. M., Dilek F. B., Karanfil, T., Yetis U., J. Clean. Prod., 130, p. 195-201, 2016.
Published
2020-06-15
How to Cite
1.
DRAGOMIR BĂLĂNICĂ CM, ZECA DE, EFTIMIE DG. Emissions of Carbon Monoxide and Suspended Particles from the Steel Foundry of S.C. PROMEX S.A. The Annals of “Dunarea de Jos” University of Galati. Fascicle IX, Metallurgy and Materials Science [Internet]. 15Jun.2020 [cited 21Dec.2024];43(2):45-0. Available from: https://gup.ugal.ro/ugaljournals/index.php/mms/article/view/3470
Issue
Section
Articles