EXPERIMENTAL RESULTS AND A DISCRETE DYNAMIC MODEL DETERMINATION OF AN ELECTRONICALLY CONTROLLED HYDROSTATIC TRANSMISSION

  • Novakovic Miroslav Engineering College, Trstenik, Serbia
  • Cajetinac Stanimir Engineering College, Trstenik, Serbia
  • Mijatovic Milomir Engineering College, Trstenik, Serbia
Keywords: hydrostatic transmission, electronically controlled pump, discrete model identification, z-transfer function, model order and parameter estimation

Abstract

The paper presents the experimental results of a research on a hydrostatic transmission with an electronically controlled variable displacement pump. A linear discrete dynamic model is identified and a model order and the z-transfer function parameters are estimated.
The mathematical model is realized trough a procedure of identification in the local operating point of hydraulic motor.

 

Published
2011-10-17
How to Cite
Miroslav, N., Stanimir, C., & Milomir, M. (2011). EXPERIMENTAL RESULTS AND A DISCRETE DYNAMIC MODEL DETERMINATION OF AN ELECTRONICALLY CONTROLLED HYDROSTATIC TRANSMISSION. Mechanical Testing and Diagnosis, 1(1), 59-62. Retrieved from https://gup.ugal.ro/ugaljournals/index.php/mtd/article/view/2619
Section
Articles